Air Particulate Channel
Channel Category: air_particulate
Monitors the concentration of particulate matter (PM1, PM2.5, PM10) in the air, providing insights into air quality and pollution levels.
Property Constraints
⚠️
At least one property from each of the following groups must be present:
detectedorconcentration
Optional Properties
| Property | Data Type | Range/Values | Unit | Permissions |
|---|---|---|---|---|
detected | Bool | - | - | RO (Read-Only) |
concentration | Float | 0–1000 | µg/m³ | RO (Read-Only) |
mode | Enum | pm1, pm2_5, pm10 | - | RO (Read-Only) |
active | Bool | - | - | RO (Read-Only) |
fault | Uchar | 0–255 | - | RO (Read-Only) |
tampered | Bool | - | - | RO (Read-Only) |
Property Details
detected
Binary detection state (true = detected)
concentration
Measured concentration level
mode
Operating mode selection
active
Indicates if the channel/sensor is currently active and functioning
fault
Fault code or diagnostic indicator (0 = no fault)
tampered
Indicates if the device has been tampered with