Dehumidifier Channel
Channel Category: dehumidifier
Controls dehumidifier devices, including on/off state, target humidity, and operating modes.
Required Properties
| Property | Data Type | Range/Values | Unit | Permissions |
|---|---|---|---|---|
on | Bool | - | - | RW (Read-Write) |
humidity | Uchar | 0–100 | % | RW (Read-Write) |
Property Details
on
Turn the dehumidifier on or off
humidity
Target humidity level
Optional Properties
| Property | Data Type | Range/Values | Unit | Permissions |
|---|---|---|---|---|
mode | Enum | auto, manual, continuous, laundry, quiet | - | RW (Read-Write) |
status | Enum | idle, dehumidifying, defrosting | - | RO (Read-Only) |
water_tank_full | Bool | - | - | RO (Read-Only) |
water_tank_level | Uchar | 0–100 | % | RO (Read-Only) |
defrost_active | Bool | - | - | RO (Read-Only) |
timer | Ushort | 0–86400 | s | RW (Read-Write) |
locked | Bool | - | - | RW (Read-Write) |
fault | Uchar | 0–255 | - | RO (Read-Only) |
Property Details
mode
Operating mode of the dehumidifier
status
Current operational status
water_tank_full
Water tank full indicator
water_tank_level
Water tank level as percentage
defrost_active
Defrost cycle is active
timer
Auto-off timer - integrator can choose between duration or preset intervals
This property supports multiple data type variants:
- duration: Ushort (0–86400) in s - Timer duration in seconds (0-86400)
- preset: Enum (
off,30m,1h,2h,4h,8h,12h) - Preset timer intervals
locked
Child lock or panel lock state
fault
Fault code or diagnostic indicator (0 = no fault)
Last updated on